android.device.scanner.configuration
Class PropertyID

java.lang.Object
  extended by android.device.scanner.configuration.PropertyID

public final class PropertyID
extends java.lang.Object


Field Summary
static int AUSTRALIAN_POST_ENABLE
This property specifies whether Australia Post decoding is enabled.
static int AZTEC_ENABLE
This property specifies whether Aztec Code decoding is enabled.
static int AZTEC_INVERSE
Set the Aztec inverse decoder setting: Regular Only/ Inverse Only/ Inverse Autodetect. Note: The parameter values below are ONLY supported on platforms interfacing to the Zebra Technologies imagers.
static int C25_ENABLE
This property specifies whether chinese 2 of 5 post decoding is enabled.
static int CODABAR_CLSI
Enable this parameter to strip the start and stop characters and insert a space after the first, fifth, and tenth characters of a 14-character Codabar symbol.
static int CODABAR_ENABLE
This property specifies whether Codabar decoding is enabled.
static int CODABAR_ENABLE_CHECK
This property specifies whether Codabar check digit verification is enable.
static int CODABAR_LENGTH1
Set minimun length for Codabar. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int CODABAR_LENGTH2
Set maximun length for Codabar. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int CODABAR_NOTIS
Enable this parameter to strip the start and stop characters from a decoded Codabar symbol.
static int CODABAR_SEND_CHECK
This property specifies whetherto transmit Codabar data with or without the check digit.
static int CODABAR_SEND_START
Start/Stop characters identify the leading and trailing ends of the bar code.
static int CODE_ISBT_128
ISBT 128 is a variant of Code128 used in the blood bank industry.
static int CODE_ISBT_Concatenation_MODE
Select an option for concatenating pairs of ISBT code types:
0 : Disable ISBT Concatenation - The device does not concatenate pairs of ISBT codes it encounters.
static int CODE11_ENABLE
This property specifies whether Codes11 decoding is enabled.
static int CODE11_ENABLE_CHECK
This feature allows the decoder to check the integrity of all Code11 symbols to verify that the data complies with the specified check digit algorithm.
static int CODE11_LENGTH1
Set minimun length for Code11. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int CODE11_LENGTH2
Set maximun length for Code11. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int CODE11_SEND_CHECK
This property specifies whether or not to transmit the Code11 check digit(s).
static int CODE128_CHECK_ISBT_TABLE
The ISBT specification includes a table that lists several types of ISBT bar codes that are commonly used in pairs.
static int CODE128_ENABLE
This property specifies whether Code128 decoding is enabled.
static int CODE128_GS1_ENABLE
This property specifies whether GS1-128 decoding is enabled.
static int CODE128_IGNORE_FNC4
This feature applies to Code128 bar codes with an embedded character.
0 : Disable Ignore Code128; The character is not transmitted but the following character has 128 added to it.
1 : Enable Ignore Code128; This strips the character from the decode data. The remaining characters do not change.
static int CODE128_LENGTH1
Set minimun length for Code128. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int CODE128_LENGTH2
Set maximun length for Code128. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int CODE128_REDUCED_QUIET_ZONE
Enable or disable decoding Code128 bar codes with reduced quiet zones. The property value should be set as follows:
0 : Disallow short quiet zone symbols.
static int CODE128_SECURITY_LEVEL
Code128 bar codes are vulnerable to misdecodes, particularly when Code128 Lengths is set to Any Length.
static int CODE32_ENABLE
This property specifies whether Code32 decoding is enabled.
static int CODE32_SEND_START
Enable or disable adding the prefix character “A” to all Code32 bar codes.
static int CODE39_ENABLE
This property specifies whether Code39 decoding is enabled.
static int CODE39_ENABLE_CHECK
Enable this to check the integrity of all Code39 symbols to verify that the data complies with specified check digit algorithm.
static int CODE39_FULL_ASCII
Code39 Full ASCII is a variant of Code39 which pairs characters to encode the full ASCII character set.
static int CODE39_LENGTH1
Set minimun length for Code39. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int CODE39_LENGTH2
Set maximun length for Code39. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int CODE39_Quiet_Zone
Enable or disable decoding Code39 bar codes with reduced quiet zones.
static int CODE39_SECURITY_LEVEL
The scanner offers four levels of decode security for Code39 barcodes.
static int CODE39_SEND_CHECK
This property specifies whether to transmit Code39 data with or without the check digit.
static int CODE39_START_STOP
Start/Stop characters identify the leading and trailing ends of the bar code.
static int CODE93_ENABLE
This property specifies whether Codabar decoding is enabled.
static int CODE93_LENGTH1
Set minimun length for Code39. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int CODE93_LENGTH2
Set maximun length for Code39. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int CODING_FORMAT
This property specifies the character encoding to use for the bar code data.
static int COMPOSITE_CC_AB_ENABLE
This property specifies whether Composite CC-A/B decoding is enabled.
static int COMPOSITE_CC_C_ENABLE
This property specifies whether Composite CC-C decoding is enabled.
static int COMPOSITE_TLC39_ENABLE
This property specifies whether Composite TLC-39 decoding is enabled.
static int D25_ENABLE
This property specifies whether Discrete 2 of 5 decoding is enabled.
static int D25_LENGTH1
Set minimun length for Discrete 2 of 5. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int D25_LENGTH2
Set maximun length for Discrete 2 of 5. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int DATAMATRIX_ENABLE
This property specifies whether DataMatrix decoding is enabled.
static int DATAMATRIX_INVERSE
Set the DATAMATRIX inverse decoder setting: Regular Only/ Inverse Only/ Inverse Autodetect. Note: The parameter values below are only supported on platforms interfacing to the Zebra Technologies imagers.
static int DATAMATRIX_LENGTH1
Set minimun length for DataMatrix. Range: 1 to 3166. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int DATAMATRIX_LENGTH2
Set minimun length for DataMatrix. Range: 1 to 3166. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int DEC_2D_CENTERING_ENABLE
This property specifies whether Centering mode decoding is enabled.
static int DEC_2D_CENTERING_MODE
Mode Configuration settings:Off/Around Aimer/Field Of View. Note: The parameter values below are ONLY supported on platforms interfacing to the Honeywell 6703/6603 scanner.
static int DEC_2D_LIGHTS_MODE
This property specifies whether the lights mode settings. Lights Configuration settings:(Illum/Aimer Off)/(Aimer Only)/(Illum Only)/(Alternating)/(Concurrent).
static int DEC_2D_WINDOW_LOWER_RX
Upper right X coordinate setting : default 386, min 0, max 415.
static int DEC_2D_WINDOW_LOWER_RY
Upper right Y coordinate setting : default 446, min 416, max 831.
static int DEC_2D_WINDOW_UPPER_LX
Upper left X coordinate setting : default 290, min 0, max 319.
static int DEC_2D_WINDOW_UPPER_LY
Upper left Y coordinate setting :default 350, min 320, max 639.
static int DEC_ES_CONFORM_IMAGE
The image must conform to the auto-exposure requirements, if not, it's rejected. Valid Values: Rang 0to 1.
static int DEC_ES_CONFORM_TRIES
The number of time it will attempt to conform Valid Values: Rang 1 to 8.
static int DEC_ES_FIXED_FRAME_RATE
If exposure mode is FIXED, what is the frame rate (fixed, has no effect) Valid Values: Rang 1 to 30.
static int DEC_ES_FIXED_GAIN
If exposure mode is FIXED, what is the gain Valid Values: Rang 1 to 4.
static int DEC_ES_MAX_EXP
This is the maximum exposure allowed to use Valid Values: Rang 1 to 7874.
static int DEC_ES_MAX_GAIN
This is the maximum gain allowed to use Valid Values: Rang 1 to 4.
static int DEC_ES_TARGET_ACCEPT_GAP
How close to the target while value must image be Valid Values: Rang 1 to 50.
static int DEC_ES_TARGET_PERCENTILE
The percentile the white target value should be at Valid Values: Rang 1 to 99.
static int DEC_ES_TARGET_VALUE
Target white value in image to try and achieve Valid Values: Rang 1 to 255.
static int DEC_OCR_MODE
Note: The parameter values below are ONLY supported on platforms interfacing to the Honeywell 6703/6603 scanner.
static int DEC_OCR_TEMPLATE
Note: The parameter values below are ONLY supported on platforms interfacing to the Honeywell 6703/6603 scanner.
static int DEC_OCR_USER_TEMPLATE
Note: The parameter values below are ONLY supported on platforms interfacing to the Honeywell 6703/6603 scanner.
static int DEC_ILLUM_POWER_LEVEL
This parameter sets the level of illumination by altering laser/LED power. Power Level(1/2/3/4/5/6/7).
static int DEC_PICKLIST_AIM_DELAY
Note: The parameter values below are ONLY supported on platforms interfacing to the Honeywell 3680 scanner.
static int DEC_PICKLIST_AIM_MODE
Note: The parameter values below are ONLY supported on platforms interfacing to the Honeywell 3680 scanner.
static int DOTCODE_ENABLE
This property specifies whether Dotcode decoding is enabled.
static int DPM_DECODE_MODE
This property specifies whether DPM decoding is enabled during the execution of Decode.
static int EAN_EXT_ENABLE_2_5_DIGIT
This parameter determines whether or not EAN supplemental 2/5 should be transmitted.
static int EAN13_BOOKLAND_FORMAT
Select one of the following formats for Bookland data:
0 : Bookland ISBN-10; The decoder reports Bookland data starting with 978 in traditional 10-digit format with the special Bookland check digit for backward-compatibility.
static int EAN13_BOOKLANDEAN
This property specifies Enable or disable Bookland EAN.
static int EAN13_ENABLE
This property specifies whether EAN-13 decoding is enabled.
static int EAN13_SEND_CHECK
This property specifies whether transmit EAN-13 check digit.
static int EAN8_ENABLE
This property specifies whether EAN-8 decoding is enabled.
static int EAN8_SEND_CHECK
This property specifies whether transmit EAN-8 check digit.
static int EAN8_TO_EAN13
Enable this parameter to add five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.
static int FULL_READ_MODE
Note: The property value below is ONLY supported on platforms interfacing to the Zebra Technologies imagers.
static int FUZZY_1D_PROCESSING
This option is enabled by default to optimize decode performance on 1D bar codes, including damaged and poor quality symbols.
static int GOOD_READ_BEEP_ENABLE
To set Scanner success beep when keystroke output enable WEDGE_KEYBOARD_ENABLE. Select valid value from the following options:
0 : None
1 : Short
2 : Sharp
static int GOOD_READ_VIBRATE_ENABLE
To set Scanner success vibrate when keystroke output enable.
static int GS1_14_ENABLE
This property specifies whether GS1 DataBar-14 decoding is enabled.
static int GS1_14_TO_UPC_EAN
This parameter only applies to GS1 DataBar-14 and GS1 DataBar Limited symbols not decoded as part of a Composite symbol.
static int GS1_EXP_ENABLE
This property specifies whether GS1 DataBar Expanded decoding is enabled.
static int GS1_EXP_LENGTH1
Set minimun length for GS1 DataBar Expanded. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int GS1_EXP_LENGTH2
Set maximun length for GS1 DataBar Expanded. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int GS1_LIMIT_ENABLE
This property specifies whether GS1 DataBar Limited decoding is enabled.
static int GS1_LIMIT_Security_Level
There are four levels of decode security for GS1 DataBar Limited bar codes.
static int GS1128__UCCEAN_Composite
GS1-128 Emulation Mode for UCC/EAN Composite Codes.
static int HANXIN_ENABLE
This property specifies whether Han Xin decoding is enabled.
static int HANXIN_INVERSE
Note: The parameter values below are ONLY supported on platforms interfacing to the Zebra Technologies imagers.
static int I25_ENABLE
This property specifies whether Interleaved 2 of 5 decoding is enabled.
static int I25_ENABLE_CHECK
Enable this feature to check the integrity of all I 2 of 5 symbols to verify the data complies with either the specified Uniform Symbology Specification (USS), or the Optical Product Code Council (OPCC) check digit algorithm.
static int I25_LENGTH1
Set minimun length for Interleaved 2 of 5. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int I25_LENGTH2
Set maximun length for Interleaved 2 of 5. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int I25_QUIET_ZONE
Enable or disable decoding I 2 of 5 bar codes with reduced quiet zones The property value should be set as follows:
0: Disallow short quiet zone symbols.
static int I25_SECURITY_LEVEL
Interleaved 2 of 5 bar codes are vulnerable to misdecodes, particularly when I 2 of 5 Lengths is set to Any Length.
static int I25_SEND_CHECK
This property specifies whetherto transmit I 2 of 5 data with or without the check digit.
static int I25_TO_EAN13
Enable this parameter to convert 14-character I 2 of 5 codes to EAN-13, and transmit to the host as EAN-13.
static int IMAGE_EXPOSURE_MODE
This property specifies the exposure mode that will be used during image capture.
static int IMAGE_FIXED_EXPOSURE
If exposure mode is FIXED, what is the exposure IMAGE_FIXED_EXPOSURE.
static int IMAGE_ONE_D_INVERSE
This property specifies whether the 1D inverse decoder setting:
0 : Regular Only; the decoder decodes regular 1D bar codes only.
static int IMAGE_PICKLIST_MODE
To set 2D Scanner Mobile Phone/Display Mode. This mode improves bar code reading performance on mobile phones and electronic displays.
static int JAPANESE_POST_ENABLE
This property specifies whether Japan Postal decoding is enabled.
static int KIX_CODE_ENABLE
This property specifies whether Netherlands KIX Code decoding is enabled.
static int LABEL_APPEND_ENTER
To set Scanner success append the action key character when keystroke output enable. Select valid value from the following options:
0 : None
1 : Carriage return
2 : IME action done
3 : TAB
static int LABEL_FORMAT_SEPARATOR_CHAR
When a bar code is scanned, the bar code data contains the Group Seperator char will hava replace LABEL_SEPARATOR_ENABLE.
static int LABEL_MATCHER_PATTERN
When a bar code is scanned, changed the bar code data with this form of regular expression.
static int LABEL_MATCHER_REPLACEMENT
When a bar code is scanned, with the Hex value characters to replace the bar code data, if it is contains LABEL_MATCHER_TARGETREGEX setting hex characters.
static int LABEL_MATCHER_TARGETREGEX
When a bar code is scanned, the bar code data contains the Hex value characters will hava replace LABEL_MATCHER_REPLACEMENT set the replace source characters are Hex value characters.Example:this “j” Hex ID is “6A”.
static int LABEL_PREFIX
When a bar code is scanned, additional Prefix characters is sent to the App along with the bar code data.
static int LABEL_SEPARATOR_ENABLE
This property specifies whether the bar code data replace the separator char LABEL_FORMAT_SEPARATOR_CHAR.
static int LABEL_SUFFIX
When a bar code is scanned, additional Suffix characters is sent to the App along with the bar code data.
static int LASER_ON_TIME
Set the maximum time decode processing continues during a scan attempt.
static int LINEAR_1D_QUIET_ZONE_LEVEL
This feature sets the level of aggressiveness in decoding bar codes with a reduced quiet zone (the area in front of and at the end of a bar code), and applies to symbologies enabled by a Reduced Quiet Zone parameter.
static int LINEAR_CODE_TYPE_SECURITY_LEVEL
To set Scanner linear code type security level. Parameters Values:0 to 3, default 1.
static int M25_ENABLE
This property specifies whether Matrix 2 of 5 decoding is enabled.
static int M25_ENABLE_CHECK
The check digit is the last character of the symbol used to verify the integrity of the data.
static int M25_LENGTH1
Set minimun length for Matrix 2 of 5. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int M25_LENGTH2
Set maximun length for Matrix 2 of 5. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int M25_SEND_CHECK
This property specifies whether to transmit Matrix 2 of 5 data with or without the check digit.
static int MAXICODE_ENABLE
This property specifies whether MaxiCode decoding is enabled.
static int MICROPDF417_ENABLE
This property specifies whether MicroPDF417 decoding is enabled.
static int MICROQRCODE_ENABLE
This property specifies whether MicroQR Code decoding is enabled.
static int MSI_CHECK_2_MOD_11
Select one of two algorithms for the verification of the second MSI check digit:
1 : MOD 10/MOD 10
0 : MOD 10/MOD 11
static int MSI_ENABLE
This property specifies whether MSI decoding is enabled.
static int MSI_LENGTH1
Set minimun length for MSI. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int MSI_LENGTH2
Set maximun length for MSI. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
static int MSI_REQUIRE_2_CHECK
With MSI symbols, one check digit is mandatory and always verified by the reader.
static int MSI_SEND_CHECK
Select whether to transmit MSI data with or without the check digit.
static int PDF417_ENABLE
This property specifies whether PDF417 decoding is enabled.
static int QRCODE_ENABLE
This property specifies whether QR Code decoding is enabled.
static int QRCODE_INVERSE
Note: The parameter values below are ONLY supported on platforms interfacing to the Zebra Technologies imagers.
static int REMOVE_NONPRINT_CHAR
This property specifies whether the bar code data remove the nonprint char.
static int ROYAL_MAIL_ENABLE
This property specifies whether ROYAL mail decoding is enabled.
static int SEND_GOOD_READ_BEEP_ENABLE
To set Scanner success beep or vibrate when SendBroadcast. SendBroadcast Values:
WEDGE_INTENT_ACTION_NAME and WEDGE_INTENT_DATA_STRING_TAG.
static int SEND_GOOD_READ_VIBRATE_ENABLE
To set Scanner success vibrate when SendBroadcast. SendBroadcast Values:
WEDGE_INTENT_ACTION_NAME and WEDGE_INTENT_DATA_STRING_TAG.
static int SEND_LABEL_PREFIX_SUFFIX
This property specifies whether Data format mode.
static int TIMEOUT_BETWEEN_SAME_SYMBOL
To set Scanner decoding timeout between same symbol.
Parameters Values: value * 100 ms; value is 1 to 99, default 10.
static int TRANSMIT_CODE_ID
A Code ID character identifies the code type of a scanned bar code.
static int TRIGGERING_LOCK
This property specifies whether the scan trigger inactive (disable the scan button).
static int TRIGGERING_MODES
To set Scanner trigger modes.
Parameters Values: Triggering
static int TRIOPTIC_ENABLE
This property specifies whether Trioptic decoding is enabled.
static int UCC_COUPON_EXT_CODE
Enable this parameter to decode UPC-A bar codes starting with digit ‘5’, EAN-13 bar codes starting with digit ‘99’, and UPC-A/EAN-128 Coupon Codes.
static int UCC_COUPON_EXT_REPORT_MODE
Traditional coupon symbols (old coupon symbols) are composed of two bar codes: UPC/EAN and Code128.
static int UCC_EAN_ZERO_EXTEND
Enable this parameter to add five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.
static int UCC_REDUCED_QUIET_ZONE
Enable or disable decoding UPC bar codes with reduced quiet zones.
static int UPC_EAN_SECURITY_LEVEL
To set Scanner linear code type security level. Parameters Values: 0 to 3, default 1.
static int UPCA_ENABLE
This property specifies whether UPC-A decoding is enabled.
static int UPCA_SEND_CHECK
The check digit is the last character of the symbol used to verify the integrity of the data.
static int UPCA_SEND_SYS
Preamble characters are part of the UPC symbol, and include Country Code and System Character.
static int UPCA_TO_EAN13
When UPC-A Converted to EAN-13 is selected, UPC-A bar codes are converted to 13 digit EAN-13 codes by adding a zero to the front.
static int UPCE_ENABLE
This property specifies whether UPC-E decoding is enabled.
static int UPCE_SEND_CHECK
The check digit is the last character of the symbol used to verify the integrity of the data.
static int UPCE_SEND_SYS
Preamble characters are part of the UPC symbol, and include Country Code and System Character.
static int UPCE_TO_UPCA
Enable this to convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission.
static int UPCE1_ENABLE
This property specifies whether UPC-E1 decoding is enabled.
static int UPCE1_SEND_CHECK
The check digit is the last character of the symbol used to verify the integrity of the data.
static int UPCE1_SEND_SYS
Preamble characters are part of the UPC symbol, and include Country Code and System Character.
static int UPCE1_TO_UPCA
Enable this to convert UPC-E1 decoded data to UPC-A format before transmission.
static int UPU_FICS_ENABLE
This property specifies whether UPU FICS Postal decoding is enabled.
static int US_PLANET_ENABLE
This property specifies whether US Planet decoding is enabled.
static int US_POSTAL_SEND_CHECK
Select whether to transmit US Postal data, which includes both US Postnet and US Planet, with or without the check digit.
static int US_POSTNET_ENABLE
This property specifies whether US Postnet/US Postal decoding is enabled.
static int USPS_4STATE_ENABLE
This property specifies whether USPS 4CB/One Code/Intelligent Mail decoding is enabled.
static int WEDGE_INTENT_ACTION_NAME
The intent action name is to receive barcode data. The default is "android.intent.ACTION_DECODE_DATA".
static int WEDGE_INTENT_DATA_STRING_TAG
A string tag represents the barcode string. The default is "barcode_string".
static int WEDGE_INTENT_LABEL_TYPE_TAG
A string tag represents the barcode type. The default is "barcodeType".
static int WEDGE_KEYBOARD_ENABLE
This property specifies whether Keyboard mode is enabled. If the configured PropertyID.WEDGE_KEYBOARD_ENABLE is 1, append the barcode text to TextBox, input method, or send the barcode text as key events.
static int WEDGE_KEYBOARD_TYPE
This property specifies select an option for keystroke types. Values:
0 : Auto append text to TextBox.
1 : If there is no TextBox, append text to input method.
2 : Send key event.
3 : Auto append text to input method.
 
Constructor Summary
PropertyID()
PropertyID class contains all supported Scanner sub-system reader properties.
 
Method Summary
 
Methods inherited from class java.lang.Object
equals, getClass, hashCode, notify, notifyAll, toString, wait, wait, wait
 

FIELD DETAIL

SEND_GOOD_READ_BEEP_ENABLE

public static final int SEND_GOOD_READ_BEEP_ENABLE
To set Scanner success beep or vibrate when SendBroadcast. SendBroadcast Values:
WEDGE_INTENT_ACTION_NAME and WEDGE_INTENT_DATA_STRING_TAG.

See Also:
Constant Field Values

SEND_GOOD_READ_VIBRATE_ENABLE

public static final int SEND_GOOD_READ_VIBRATE_ENABLE
To set Scanner success vibrate when SendBroadcast. SendBroadcast Values:
WEDGE_INTENT_ACTION_NAME and WEDGE_INTENT_DATA_STRING_TAG.
See Also:
Constant Field Values

TRIGGERING_MODES

public static final int TRIGGERING_MODES
To set Scanner trigger modes
Parameters Values: Triggering

See Also:
Constant Field Values

GOOD_READ_BEEP_ENABLE

public static final int GOOD_READ_BEEP_ENABLE
To set Scanner success beep when keystroke output enable WEDGE_KEYBOARD_ENABLE. Select valid value from the following options:
0 : None
1 : Short
2 : Sharp
See Also:
Constant Field Values

GOOD_READ_VIBRATE_ENABLE

public static final int GOOD_READ_VIBRATE_ENABLE
To set Scanner success vibrate when keystroke output enable.
See Also:
Constant Field Values

LABEL_APPEND_ENTER

public static final int LABEL_APPEND_ENTER
To set Scanner success append the action key character when keystroke output enable. Select valid value from the following options:
0 : None
1 : Carriage return
2 : IME action done
3 : TAB
See Also:
Constant Field Values

LABEL_FORMAT_SEPARATOR_CHAR

public static final int LABEL_FORMAT_SEPARATOR_CHAR
When a bar code is scanned, the bar code data contains the Group Seperator char will hava replace LABEL_SEPARATOR_ENABLE.
See Also:
Constant Field Values

IMAGE_PICKLIST_MODE

public static final int IMAGE_PICKLIST_MODE
To set 2D Scanner Mobile Phone/Display Mode.This mode improves bar code reading performance on mobile phones and electronic displays.

See Also:
Constant Field Values

TRANSMIT_CODE_ID

public static final int TRANSMIT_CODE_ID
A Code ID character identifies the code type of a scanned bar code.
See Also:
Constant Field Values

TRIGGERING_LOCK

public static final int TRIGGERING_LOCK
This property specifies whether the scan trigger inactive (disable the scan button).
See Also:
Constant Field Values

IMAGE_ONE_D_INVERSE

public static final int IMAGE_ONE_D_INVERSE
This property specifies whether the 1D inverse decoder setting:
0 : Regular Only; the decoder decodes regular 1D bar codes only.

See Also:
Constant Field Values

LABEL_MATCHER_PATTERN

public static final int LABEL_MATCHER_PATTERN
When a bar code is scanned, changed the bar code data with this form of regular expression.
See Also:
Constant Field Values

LABEL_MATCHER_REPLACEMENT

public static final int LABEL_MATCHER_REPLACEMENT
When a bar code is scanned, with the Hex value characters to replace the bar code data, if it is contains LABEL_MATCHER_TARGETREGEX setting hex characters.
See Also:
Constant Field Values

LABEL_MATCHER_TARGETREGEX

public static final int LABEL_MATCHER_TARGETREGEX
When a bar code is scanned, the bar code data contains the Hex value characters will hava replace LABEL_MATCHER_REPLACEMENT set the replace source characters are Hex value characters.Example:this “j” Hex ID is “6A”.
See Also:
Constant Field Values

SEND_LABEL_PREFIX_SUFFIX

public static final int SEND_LABEL_PREFIX_SUFFIX
This property specifies whether Data format mode.
See Also:
Constant Field Values

LABEL_PREFIX

public static final int LABEL_PREFIX
When a bar code is scanned, additional Prefix characters is sent to the App along with the bar code data.
See Also:
Constant Field Values

LABEL_SEPARATOR_ENABLE

public static final int LABEL_SEPARATOR_ENABLE
This property specifies whether the bar code data replace the separator char LABEL_FORMAT_SEPARATOR_CHAR.
See Also:
Constant Field Values

LABEL_SUFFIX

public static final int LABEL_SUFFIX
When a bar code is scanned, additional Suffix characters is sent to the App along with the bar code data.
See Also:
Constant Field Values

LASER_ON_TIME

public static final int LASER_ON_TIME
Set the maximum time decode processing continues during a scan attempt.

See Also:
Constant Field Values

TIMEOUT_BETWEEN_SAME_SYMBOL

public static final int TIMEOUT_BETWEEN_SAME_SYMBOL
To set Scanner decoding timeout between same symbol.
Parameters Values: value * 100 ms; value is 1 to 99, default 10.

See Also:
Constant Field Values

LINEAR_1D_QUIET_ZONE_LEVEL

public static final int LINEAR_1D_QUIET_ZONE_LEVEL
This feature sets the level of aggressiveness in decoding bar codes with a reduced quiet zone (the area in front of and at the end of a bar code), and applies to symbologies enabled by a Reduced Quiet Zone parameter.

See Also:
Constant Field Values

LINEAR_CODE_TYPE_SECURITY_LEVEL

public static final int LINEAR_CODE_TYPE_SECURITY_LEVEL
To set Scanner linear code type security level. Parameters Values:0 to 3, default 1.

See Also:
Constant Field Values

FULL_READ_MODE

public static final int FULL_READ_MODE
Note: The property value below is ONLY supported on platforms interfacing to the Zebra Technologies imagers.
See Also:
Constant Field Values

FUZZY_1D_PROCESSING

public static final int FUZZY_1D_PROCESSING
This option is enabled by default to optimize decode performance on 1D bar codes, including damaged and poor quality symbols.
See Also:
Constant Field Values

CODING_FORMAT

public static final int CODING_FORMAT
This property specifies the character encoding to use for the bar code data.
See Also:
Constant Field Values

IMAGE_EXPOSURE_MODE

public static final int IMAGE_EXPOSURE_MODE
This property specifies the exposure mode that will be used during image capture.
See Also:
Constant Field Values

IMAGE_FIXED_EXPOSURE

public static final int IMAGE_FIXED_EXPOSURE
If exposure mode is FIXED, what is the exposure IMAGE_FIXED_EXPOSURE.
See Also:
Constant Field Values

CODE39_ENABLE

public static final int CODE39_ENABLE
This property specifies whether Code39 decoding is enabled.
See Also:
Constant Field Values

CODE39_ENABLE_CHECK

public static final int CODE39_ENABLE_CHECK
Enable this to check the integrity of all Code39 symbols to verify that the data complies with specified check digit algorithm.
See Also:
Constant Field Values

CODE39_SEND_CHECK

public static final int CODE39_SEND_CHECK
This property specifies whether to transmit Code39 data with or without the check digit.
See Also:
Constant Field Values

CODE39_START_STOP

public static final int CODE39_START_STOP
Start/Stop characters identify the leading and trailing ends of the bar code.
See Also:
Constant Field Values

CODE39_FULL_ASCII

public static final int CODE39_FULL_ASCII
Code39 Full ASCII is a variant of Code39 which pairs characters to encode the full ASCII character set.
See Also:
Constant Field Values

CODE39_LENGTH1

public static final int CODE39_LENGTH1
Set minimun length for Code39. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

CODE39_LENGTH2

public static final int CODE39_LENGTH2
Set maximun length for Code39. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

CODE39_Quiet_Zone

public static final int CODE39_Quiet_Zone
Enable or disable decoding Code39 bar codes with reduced quiet zones.
See Also:
Constant Field Values

CODE39_SECURITY_LEVEL

public static final int CODE39_SECURITY_LEVEL
The scanner offers four levels of decode security for Code39 barcodes.
See Also:
Constant Field Values

TRIOPTIC_ENABLE

public static final int TRIOPTIC_ENABLE
This property specifies whether Trioptic decoding is enabled.
See Also:
Constant Field Values

CODE32_ENABLE

public static final int CODE32_ENABLE
This property specifies whether Code32 decoding is enabled.
See Also:
Constant Field Values

CODE32_SEND_START

public static final int CODE32_SEND_START
Enable or disable adding the prefix character “A” to all Code32 bar codes.
See Also:
Constant Field Values

C25_ENABLE

public static final int C25_ENABLE
This property specifies whether chinese 2 of 5 post decoding is enabled.
See Also:
Constant Field Values

D25_ENABLE

public static final int D25_ENABLE
This property specifies whether Discrete 2 of 5 decoding is enabled.
See Also:
Constant Field Values

D25_LENGTH1

public static final int D25_LENGTH1
Set minimun length for Discrete 2 of 5. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

D25_LENGTH2

public static final int D25_LENGTH2
Set maximun length for Discrete 2 of 5. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

M25_ENABLE

public static final int M25_ENABLE
This property specifies whether Matrix 2 of 5 decoding is enabled.
See Also:
Constant Field Values

M25_ENABLE_CHECK

public static final int M25_ENABLE_CHECK
The check digit is the last character of the symbol used to verify the integrity of the data.
See Also:
Constant Field Values

M25_LENGTH1

public static final int M25_LENGTH1
Set minimun length for Matrix 2 of 5. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

M25_LENGTH2

public static final int M25_LENGTH2
Set maximun length for Matrix 2 of 5. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

M25_SEND_CHECK

public static final int M25_SEND_CHECK
This property specifies whether to transmit Matrix 2 of 5 data with or without the check digit.
See Also:
Constant Field Values

CODE11_ENABLE

public static final int CODE11_ENABLE
This property specifies whether Code11 decoding is enabled.
See Also:
Constant Field Values

CODE11_ENABLE_CHECK

public static final int CODE11_ENABLE_CHECK
This feature allows the decoder to check the integrity of all Code11 symbols to verify that the data complies with the specified check digit algorithm.
See Also:
Constant Field Values

CODE11_SEND_CHECK

public static final int CODE11_SEND_CHECK
This property specifies whether or not to transmit the Code11 check digit(s).
See Also:
Constant Field Values

CODE128_CHECK_ISBT_TABLE

public static final int CODE128_CHECK_ISBT_TABLE
The ISBT specification includes a table that lists several types of ISBT bar codes that are commonly used in pairs.
See Also:
Constant Field Values

CODE11_LENGTH1

public static final int CODE11_LENGTH1
Set minimun length for Code11. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

CODE11_LENGTH2

public static final int CODE11_LENGTH2
Set maximun length for Code11. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

I25_ENABLE

public static final int I25_ENABLE
This property specifies whether Interleaved 2 of 5 decoding is enabled.
See Also:
Constant Field Values

I25_ENABLE_CHECK

public static final int I25_ENABLE_CHECK
Enable this feature to check the integrity of all I 2 of 5 symbols to verify the data complies with either the specified Uniform Symbology Specification (USS), or the Optical Product Code Council (OPCC) check digit algorithm.
See Also:
Constant Field Values

I25_SEND_CHECK

public static final int I25_SEND_CHECK
This property specifies whetherto transmit I 2 of 5 data with or without the check digit.
See Also:
Constant Field Values

I25_LENGTH1

public static final int I25_LENGTH1
Set minimun length for Interleaved 2 of 5. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

I25_LENGTH2

public static final int I25_LENGTH2
Set maximun length for Interleaved 2 of 5. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

I25_QUIET_ZONE

public static final int I25_QUIET_ZONE
Enable or disable decoding I 2 of 5 bar codes with reduced quiet zones The property value should be set as follows:
0: Disallow short quiet zone symbols.
See Also:
Constant Field Values

I25_SECURITY_LEVEL

public static final int I25_SECURITY_LEVEL
Interleaved 2 of 5 bar codes are vulnerable to misdecodes, particularly when I 2 of 5 Lengths is set to Any Length.
See Also:
Constant Field Values

I25_TO_EAN13

public static final int I25_TO_EAN13
Enable this parameter to convert 14-character I 2 of 5 codes to EAN-13, and transmit to the host as EAN-13.
See Also:
Constant Field Values

CODABAR_ENABLE

public static final int CODABAR_ENABLE
This property specifies whether Codabar decoding is enabled.
See Also:
Constant Field Values

CODABAR_ENABLE_CHECK

public static final int CODABAR_ENABLE_CHECK
This property specifies whether Codabar check digit verification is enable.
See Also:
Constant Field Values

CODABAR_NOTIS

public static final int CODABAR_NOTIS
Enable this parameter to strip the start and stop characters from a decoded Codabar symbol.
See Also:
Constant Field Values

CODABAR_SEND_CHECK

public static final int CODABAR_SEND_CHECK
This property specifies whetherto transmit Codabar data with or without the check digit.
See Also:
Constant Field Values

CODABAR_SEND_START

public static final int CODABAR_SEND_START
Start/Stop characters identify the leading and trailing ends of the bar code.
See Also:
Constant Field Values

CODABAR_CLSI

public static final int CODABAR_CLSI
Enable this parameter to strip the start and stop characters and insert a space after the first, fifth, and tenth characters of a 14-character Codabar symbol.
See Also:
Constant Field Values

CODABAR_LENGTH1

public static final int CODABAR_LENGTH1
Set minimun length for Codabar. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

CODABAR_LENGTH2

public static final int CODABAR_LENGTH2
Set maximun length for Codabar. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

CODE93_ENABLE

public static final int CODE93_ENABLE
This property specifies whether Code93 decoding is enabled.
See Also:
Constant Field Values

CODE93_LENGTH1

public static final int CODE93_LENGTH1
Set minimun length for Code39. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

CODE93_LENGTH2

public static final int CODE93_LENGTH2
Set maximun length for Code39. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

CODE128_ENABLE

public static final int CODE128_ENABLE
This property specifies whether Code128 decoding is enabled.
See Also:
Constant Field Values

CODE128_LENGTH1

public static final int CODE128_LENGTH1
Set minimun length for Code128. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

CODE128_LENGTH2

public static final int CODE128_LENGTH2
Set maximun length for Code128. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

CODE128_REDUCED_QUIET_ZONE

public static final int CODE128_REDUCED_QUIET_ZONE
Enable or disable decoding Code128 bar codes with reduced quiet zones. The property value should be set as follows:
0 : Disallow short quiet zone symbols.
See Also:
Constant Field Values

CODE128_SECURITY_LEVEL

public static final int CODE128_SECURITY_LEVEL
Code128 bar codes are vulnerable to misdecodes, particularly when Code128 Lengths is set to Any Length.
See Also:
Constant Field Values

CODE_ISBT_128

public static final int CODE_ISBT_128
ISBT 128 is a variant of Code128 used in the blood bank industry.
See Also:
Constant Field Values

CODE_ISBT_Concatenation_MODE

public static final int CODE_ISBT_Concatenation_MODE
Select an option for concatenating pairs of ISBT code types:
0 : Disable ISBT Concatenation - The device does not concatenate pairs of ISBT codes it encounters.
See Also:
Constant Field Values

CODE128_GS1_ENABLE

public static final int CODE128_GS1_ENABLE
This property specifies whether GS1-128 decoding is enabled.
See Also:
Constant Field Values

CODE128_IGNORE_FNC4

public static final int CODE128_IGNORE_FNC4
This feature applies to Code128 bar codes with an embedded character.
0 : Disable Ignore Code128; The character is not transmitted but the following character has 128 added to it.
1 : Enable Ignore Code128; This strips the character from the decode data. The remaining characters do not change.
See Also:
Constant Field Values

UPCA_ENABLE

public static final int UPCA_ENABLE
This property specifies whether UPC-A decoding is enabled.
See Also:
Constant Field Values

UPCA_SEND_CHECK

public static final int UPCA_SEND_CHECK
The check digit is the last character of the symbol used to verify the integrity of the data.
See Also:
Constant Field Values

UPCA_SEND_SYS

public static final int UPCA_SEND_SYS
Preamble characters are part of the UPC symbol, and include Country Code and System Character.
See Also:
Constant Field Values

UPCA_TO_EAN13

public static final int UPCA_TO_EAN13
When UPC-A Converted to EAN-13 is selected, UPC-A bar codes are converted to 13 digit EAN-13 codes by adding a zero to the front.
See Also:
Constant Field Values

UPCE_ENABLE

public static final int UPCE_ENABLE
This property specifies whether UPC-E decoding is enabled.
See Also:
Constant Field Values

UPCE_SEND_CHECK

public static final int UPCE_SEND_CHECK
The check digit is the last character of the symbol used to verify the integrity of the data.
See Also:
Constant Field Values

UPCE_SEND_SYS

public static final int UPCE_SEND_SYS
Preamble characters are part of the UPC symbol, and include Country Code and System Character.
See Also:
Constant Field Values

UPCE_TO_UPCA

public static final int UPCE_TO_UPCA
Enable this to convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission.
See Also:
Constant Field Values

UPCE1_ENABLE

public static final int UPCE1_ENABLE
This property specifies whether UPC-E1 decoding is enabled.
See Also:
Constant Field Values

UPCE1_SEND_CHECK

public static final int UPCE1_SEND_CHECK
The check digit is the last character of the symbol used to verify the integrity of the data.
See Also:
Constant Field Values

UPCE1_SEND_SYS

public static final int UPCE1_SEND_SYS
Preamble characters are part of the UPC symbol, and include Country Code and System Character.
See Also:
Constant Field Values

UPCE1_TO_UPCA

public static final int UPCE1_TO_UPCA
Enable this to convert UPC-E1 decoded data to UPC-A format before transmission.
See Also:
Constant Field Values

EAN13_ENABLE

public static final int EAN13_ENABLE
This property specifies whether EAN-13 decoding is enabled.
See Also:
Constant Field Values

EAN13_SEND_CHECK

public static final int EAN13_SEND_CHECK
This property specifies whether transmit EAN-13 check digit.
See Also:
Constant Field Values

EAN13_BOOKLANDEAN

public static final int EAN13_BOOKLANDEAN
This property specifies Enable or disable Bookland EAN.
See Also:
Constant Field Values

EAN13_BOOKLAND_FORMAT

public static final int EAN13_BOOKLAND_FORMAT
Select one of the following formats for Bookland data:
0 : Bookland ISBN-10; The decoder reports Bookland data starting with 978 in traditional 10-digit format with the special Bookland check digit for backward-compatibility.
See Also:
Constant Field Values

EAN8_ENABLE

public static final int EAN8_ENABLE
This property specifies whether EAN-8 decoding is enabled.
See Also:
Constant Field Values

EAN8_SEND_CHECK

public static final int EAN8_SEND_CHECK
This property specifies whether transmit EAN-8 check digit.
See Also:
Constant Field Values

EAN8_TO_EAN13

public static final int EAN8_TO_EAN13
Enable this parameter to add five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.
See Also:
Constant Field Values

EAN_EXT_ENABLE_2_5_DIGIT

public static final int EAN_EXT_ENABLE_2_5_DIGIT
This parameter determines whether or not EAN supplemental 2/5 should be transmitted.
See Also:
Constant Field Values

UPC_EAN_SECURITY_LEVEL

public static final int UPC_EAN_SECURITY_LEVEL
To set Scanner linear code type security level. Parameters Values: 0 to 3, default 1.

See Also:
Constant Field Values

UCC_COUPON_EXT_CODE

public static final int UCC_COUPON_EXT_CODE
Traditional coupon symbols (old coupon symbols) are composed of two bar codes: UPC/EAN and Code128.
See Also:
Constant Field Values

UCC_COUPON_EXT_REPORT_MODE

public static final int UCC_COUPON_EXT_REPORT_MODE
Enable this parameter to add five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.
See Also:
Constant Field Values

UCC_EAN_ZERO_EXTEND

public static final int UCC_EAN_ZERO_EXTEND
Enable or disable decoding UPC bar codes with reduced quiet zones.
See Also:
Constant Field Values

UCC_REDUCED_QUIET_ZONE

public static final int UCC_REDUCED_QUIET_ZONE
Enable this parameter to decode UPC-A bar codes starting with digit ‘5’, EAN-13 bar codes starting with digit ‘99’, and UPC-A/EAN-128 Coupon Codes.
See Also:
Constant Field Values

MSI_ENABLE

public static final int MSI_ENABLE
This property specifies whether MSI decoding is enabled.
See Also:
Constant Field Values

MSI_REQUIRE_2_CHECK

public static final int MSI_REQUIRE_2_CHECK
With MSI symbols, one check digit is mandatory and always verified by the reader.
See Also:
Constant Field Values

MSI_SEND_CHECK

public static final int MSI_SEND_CHECK
Select whether to transmit MSI data with or without the check digit.
See Also:
Constant Field Values

MSI_CHECK_2_MOD_11

public static final int MSI_CHECK_2_MOD_11
Select one of two algorithms for the verification of the second MSI check digit:
1 : MOD 10/MOD 10
0 : MOD 10/MOD 11
See Also:
Constant Field Values

MSI_LENGTH1

public static final int MSI_LENGTH1
Set minimun length for MSI. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

MSI_LENGTH2

public static final int MSI_LENGTH2
Set maximun length for MSI. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

GS1_14_ENABLE

public static final int GS1_14_ENABLE
This property specifies whether GS1 DataBar-14 decoding is enabled.
See Also:
Constant Field Values

GS1_14_TO_UPC_EAN

public static final int GS1_14_TO_UPC_EAN
This parameter only applies to GS1 DataBar-14 and GS1 DataBar Limited symbols not decoded as part of a Composite symbol.
See Also:
Constant Field Values

GS1_LIMIT_ENABLE

public static final int GS1_LIMIT_ENABLE
This property specifies whether GS1 DataBar Limited decoding is enabled.
See Also:
Constant Field Values

GS1_LIMIT_Security_Level

public static final int GS1_LIMIT_Security_Level
There are four levels of decode security for GS1 DataBar Limited bar codes.
See Also:
Constant Field Values

GS1128__UCCEAN_Composite

public static final int GS1128__UCCEAN_Composite
GS1-128 Emulation Mode for UCC/EAN Composite Codes.
See Also:
Constant Field Values

GS1_EXP_ENABLE

public static final int GS1_EXP_ENABLE
This property specifies whether GS1 DataBar Expanded decoding is enabled.
See Also:
Constant Field Values

GS1_EXP_LENGTH1

public static final int GS1_EXP_LENGTH1
Set minimun length for GS1 DataBar Expanded. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

GS1_EXP_LENGTH2

public static final int GS1_EXP_LENGTH2
Set maximun length for GS1 DataBar Expanded. Range: 0 to 55. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

US_POSTNET_ENABLE

public static final int US_POSTNET_ENABLE
This property specifies whether US Postnet/US Postal decoding is enabled.
See Also:
Constant Field Values

US_PLANET_ENABLE

public static final int US_PLANET_ENABLE
This property specifies whether US Planet decoding is enabled.
See Also:
Constant Field Values

US_POSTAL_SEND_CHECK

public static final int US_POSTAL_SEND_CHECK
Select whether to transmit US Postal data, which includes both US Postnet and US Planet, with or without the check digit.
See Also:
Constant Field Values

USPS_4STATE_ENABLE

public static final int USPS_4STATE_ENABLE
This property specifies whether USPS 4CB/One Code/Intelligent Mail decoding is enabled.
See Also:
Constant Field Values

UPU_FICS_ENABLE

public static final int UPU_FICS_ENABLE
This property specifies whether UPU FICS Postal decoding is enabled.
See Also:
Constant Field Values

ROYAL_MAIL_ENABLE

public static final int ROYAL_MAIL_ENABLE
This property specifies whether ROYAL mail decoding is enabled.
See Also:
Constant Field Values

AUSTRALIAN_POST_ENABLE

public static final int AUSTRALIAN_POST_ENABLE
This property specifies whether Australia Post decoding is enabled.
See Also:
Constant Field Values

KIX_CODE_ENABLE

public static final int KIX_CODE_ENABLE
This property specifies whether Netherlands KIX Code decoding is enabled.
See Also:
Constant Field Values

JAPANESE_POST_ENABLE

public static final int JAPANESE_POST_ENABLE
This property specifies whether Japan Postal decoding is enabled.
See Also:
Constant Field Values

PDF417_ENABLE

public static final int PDF417_ENABLE
This property specifies whether PDF417 decoding is enabled.
See Also:
Constant Field Values

MICROPDF417_ENABLE

public static final int MICROPDF417_ENABLE
This property specifies whether MicroPDF417 decoding is enabled.
See Also:
Constant Field Values

COMPOSITE_CC_AB_ENABLE

public static final int COMPOSITE_CC_AB_ENABLE
This property specifies whether Composite CC-A/B decoding is enabled.
See Also:
Constant Field Values

COMPOSITE_CC_C_ENABLE

public static final int COMPOSITE_CC_C_ENABLE
This property specifies whether Composite CC-C decoding is enabled.
See Also:
Constant Field Values

COMPOSITE_TLC39_ENABLE

public static final int COMPOSITE_TLC39_ENABLE
This property specifies whether Composite TLC-39 decoding is enabled.
See Also:
Constant Field Values

HANXIN_ENABLE

public static final int HANXIN_ENABLE
This property specifies whether Han Xin decoding is enabled.
See Also:
Constant Field Values

HANXIN_INVERSE

public static final int HANXIN_INVERSE
Note: The parameter values below are ONLY supported on platforms interfacing to the Zebra Technologies imagers.
See Also:
Constant Field Values

DATAMATRIX_ENABLE

public static final int DATAMATRIX_ENABLE
This property specifies whether DataMatrix decoding is enabled.
See Also:
Constant Field Values

DATAMATRIX_LENGTH1

public static final int DATAMATRIX_LENGTH1
Set minimun length for DataMatrix. Range: 1 to 3166. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

DATAMATRIX_LENGTH2

public static final int DATAMATRIX_LENGTH2
Set minimun length for DataMatrix. Range: 1 to 3166. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
See Also:
Constant Field Values

DATAMATRIX_INVERSE

public static final int DATAMATRIX_INVERSE
Set the DATAMATRIX inverse decoder setting: Regular Only/ Inverse Only/ Inverse Autodetect. Note: The parameter values below are only supported on platforms interfacing to the Zebra Technologies imagers.
See Also:
Constant Field Values

MAXICODE_ENABLE

public static final int MAXICODE_ENABLE
This property specifies whether MaxiCode decoding is enabled.
See Also:
Constant Field Values

QRCODE_ENABLE

public static final int QRCODE_ENABLE
This property specifies whether QR Code decoding is enabled.
See Also:
Constant Field Values

MICROQRCODE_ENABLE

public static final int MICROQRCODE_ENABLE
This property specifies whether MicroQR Code decoding is enabled.
See Also:
Constant Field Values

QRCODE_INVERSE

public static final int QRCODE_INVERSE
Note: The parameter values below are ONLY supported on platforms interfacing to the Zebra Technologies imagers.
See Also:
Constant Field Values

REMOVE_NONPRINT_CHAR

public static final int REMOVE_NONPRINT_CHAR
This property specifies whether the bar code data remove the nonprint char.
See Also:
Constant Field Values

AZTEC_ENABLE

public static final int AZTEC_ENABLE
This property specifies whether Aztec Code decoding is enabled.
See Also:
Constant Field Values

AZTEC_INVERSE

public static final int AZTEC_INVERSE
Set the Aztec inverse decoder setting: Regular Only/ Inverse Only/ Inverse Autodetect. Note: The parameter values below are ONLY supported on platforms interfacing to the Zebra Technologies imagers.
See Also:
Constant Field Values

DEC_2D_LIGHTS_MODE

public static final int DEC_2D_LIGHTS_MODE
This property specifies whether the lights mode settings. Lights Configuration settings:(Illum/Aimer Off)/(Aimer Only)/(Illum Only)/(Alternating)/(Concurrent).
See Also:
Constant Field Values

DEC_2D_CENTERING_ENABLE

public static final int DEC_2D_CENTERING_ENABLE
This property specifies whether Centering mode decoding is enabled.
See Also:
Constant Field Values

DEC_2D_CENTERING_MODE

public static final int DEC_2D_CENTERING_MODE
Mode Configuration settings:Off/Around Aimer/Field Of View. Note: The parameter values below are ONLY supported on platforms interfacing to the Honeywell 6703/6603 scanner.
See Also:
Constant Field Values

DEC_2D_WINDOW_UPPER_LX

public static final int DEC_2D_WINDOW_UPPER_LX
Upper left X coordinate setting : default 290, min 0, max 319.
See Also:
Constant Field Values

DEC_2D_WINDOW_UPPER_LY

public static final int DEC_2D_WINDOW_UPPER_LY
Upper left Y coordinate setting :default 350, min 320, max 639.
See Also:
Constant Field Values

DEC_ES_CONFORM_IMAGE

public static final int DEC_ES_CONFORM_IMAGE
The image must conform to the auto-exposure requirements, if not, it's rejected. Valid Values: Rang 0to 1.
See Also:
Constant Field Values

DEC_ES_CONFORM_TRIES

public static final int DEC_ES_CONFORM_TRIES 
The number of time it will attempt to conform Valid Values: Rang 1 to 8.
See Also:
Constant Field Values

DEC_ES_FIXED_FRAME_RATE

public static final int DEC_ES_FIXED_FRAME_RATE 
If exposure mode is FIXED, what is the frame rate (fixed, has no effect) Valid Values: Rang 1 to 30.
See Also:
Constant Field Values

DEC_ES_FIXED_GAIN

public static final int DEC_ES_FIXED_GAIN 
If exposure mode is FIXED, what is the gain Valid Values: Rang 1 to 4.
See Also:
Constant Field Values

DEC_ES_MAX_EXP

public static final int DEC_ES_MAX_EXP 
This is the maximum exposure allowed to use Valid Values: Rang 1 to 7874.
See Also:
Constant Field Values

DEC_ES_MAX_GAIN

public static final int DEC_ES_MAX_GAIN 
This is the maximum gain allowed to use Valid Values: Rang 1 to 4.
See Also:
Constant Field Values

DEC_ES_TARGET_ACCEPT_GAP

public static final int DEC_ES_TARGET_ACCEPT_GAP 
How close to the target while value must image be Valid Values: Rang 1 to 50.
See Also:
Constant Field Values

DEC_ES_TARGET_PERCENTILE

public static final int DEC_ES_TARGET_PERCENTILE 
The percentile the white target value should be at Valid Values: Rang 1 to 99.
See Also:
Constant Field Values

DEC_ES_TARGET_VALUE

public static final int DEC_ES_TARGET_VALUE 
Target white value in image to try and achieve Valid Values: Rang 1 to 255.
See Also:
Constant Field Values

DEC_2D_WINDOW_LOWER_RX

public static final int DEC_2D_WINDOW_LOWER_RX
Upper right X coordinate setting : default 386, min 0, max 415.
See Also:
Constant Field Values

DEC_2D_WINDOW_LOWER_RY

public static final int DEC_2D_WINDOW_LOWER_RY
Upper right Y coordinate setting : default 446, min 416, max 831.
See Also:
Constant Field Values

DEC_OCR_MODE

public static final int DEC_OCR_MODE
Note: The parameter values below are ONLY supported on platforms interfacing to the Honeywell 6703/6603 scanner.
See Also:
Constant Field Values

DEC_OCR_TEMPLATE

public static final int DEC_OCR_TEMPLATE
Note: The parameter values below are ONLY supported on platforms interfacing to the Honeywell 6703/6603 scanner.
See Also:
Constant Field Values

DEC_OCR_USER_TEMPLATE

public static final int DEC_OCR_USER_TEMPLATE
Note: The parameter values below are ONLY supported on platforms interfacing to the Honeywell 6703/6603 scanner.
See Also:
Constant Field Values

DEC_ILLUM_POWER_LEVEL

public static final int DEC_ILLUM_POWER_LEVEL
This parameter sets the level of illumination by altering laser/LED power. Power Level(1/2/3/4/5/6/7).
See Also:
Constant Field Values

DEC_PICKLIST_AIM_DELAY

public static final int DEC_PICKLIST_AIM_DELAY
Note: The parameter values below are ONLY supported on platforms interfacing to the Honeywell 3680 scanner.
See Also:
Constant Field Values

DEC_PICKLIST_AIM_MODE

public static final int DEC_PICKLIST_AIM_MODE
Note: The parameter values below are ONLY supported on platforms interfacing to the Honeywell 3680 scanner.
See Also:
Constant Field Values

DOTCODE_ENABLE

public static final int DOTCODE_ENABLE
This property specifies whether Dotcode decoding is enabled.
See Also:
Constant Field Values

DPM_DECODE_MODE

public static final int DPM_DECODE_MODE
This property specifies whether DPM decoding is enabled during the execution of Decode.
See Also:
Constant Field Values

WEDGE_KEYBOARD_ENABLE

public static final int WEDGE_KEYBOARD_ENABLE
This property specifies whether Keyboard mode is enabled. If the configured PropertyID.WEDGE_KEYBOARD_ENABLE is 1, append the barcode text to TextBox, input method, or send the barcode text as key events.
See Also:
Constant Field Values

WEDGE_KEYBOARD_TYPE

public static final int WEDGE_KEYBOARD_TYPE
This property specifies select an option for keystroke types. Values:
0 : Auto append text to TextBox.
1 : If there is no TextBox, append text to input method.
2 : Send key event.
3 : Auto append text to input method.
See Also:
Constant Field Values

WEDGE_INTENT_ACTION_NAME

public static final int WEDGE_INTENT_ACTION_NAME
The intent action name is to receive barcode data. The default is "android.intent.ACTION_DECODE_DATA".

See Also:
ACTION_DECODE

WEDGE_INTENT_LABEL_TYPE_TAG

public static final int WEDGE_INTENT_LABEL_TYPE_TAG
A string tag represents the barcode type. The default is "barcodeType".
See Also:
BARCODE_TYPE_TAG

WEDGE_INTENT_DATA_STRING_TAG

public static final int WEDGE_INTENT_DATA_STRING_TAG
A string tag represents the barcode string. The default is "barcode_string".

See Also:
BARCODE_STRING_TAG

Constructor Detail

PropertyID

public PropertyID()
This class contains all supported Scanner sub-system reader properties.